Item Description
1 Storage tank (capacity 3 l)
2 Sight glass
5 Name plate
6 Filter and breather

Connections
A To the mechanical seal
B Filling via pipe connection
C Filling via filling filter

QFT6000

Features

Quench fluid supply systems are used to supply single mechanical seals. They act as a convenient fluid reservoir. The QFT6000 stainless steel tank is equipped with a sight-glass for monitoring the MIN/MAX filling level and can be fastened with a lug fixture.

Supply of mechnical seal in accordance with API 682 / ISO 21049, Plan 51.

Advantages

  • Sight-glass for MIN/MAX monitoring has a large indicator area
  • Filling is possible via a filling filter or a separate pipe connection
  • Combined filling and ventilation filter in the quench fluid tank for reliable operation
  • Tank made of 1.4571: high resistance to corrosive media

Functional description

Quench fluid systems (Plan 51) are employed:
  • to absorb leakage
  • to monitor the leakage rate (e.g. through periodic reading of the level in the tank)
  • to prevent icing
  • to protect against dry running
  • to stabilize the lubricating film
  • to exclude air from the media in order to prevent a reaction with oxygen in the air



Product variants

Designation QFT6000/M001-D0 QFT6000A4M001-D0
Volume (liters) 3 3
Allowable pressure Pressureless Pressureless
Allowable temperature -20 °C ... +80 °C
(-4 °F ... +176 °F)
-20 °C ... +100 °C
(-4 °F ... +212 °F)
Material, tank
1.4571
Material, filling filter
Glass-fibre reinforced polyamide
Material, inspection glass
Glass/FKM
Borosilicate/PTFE
Process connections
1/2" NPT (f)
Execution
API 682 3rd Edition
API 682 4th Edition



QFT6000A4M001-D0 Quench system according to API 682, 4th edition.

Similar products

QFT1000

Quench fluid supply systems are used to supply single or tandem mechanical seals. They act as a convenient fluid reservoir. The exchange of fluid takes place by the thermosiphon principle or by forced circulation, e.g. with a pumping screw. The QFT1000 is made of transparent polyethylene, complete with clips made of stainless steel. The QFT1000 is resistant to water, glycerine, glycols and methanol; not resistant to mineral oils and toluene.

Supply of mechanical seal based on API 682 / ISO 21049, Plan 51.

QFT2000

Quench fluid supply systems are used to supply single or tandem mechanical seals. They act as a convenient fluid reservoir. The exchange of fluid takes place by the thermosiphon principle or by forced circulation, e.g. with a pumping screw. The QFT2000 stainless steel tank is equipped with sight-glasses for monitoring the MIN/MAX level and can be fastened with a lug fixture. The leakage overflow can be selectively discharged.

Supply of mechanical seal based on API 682 / ISO 21049, Plan 51.

QFT3000

Quench fluid supply systems are used to supply single or tandem mechanical seals. They act as a convenient fluid reservoir. The exchange of fluid takes place by the thermosiphon principle or by forced circulation, e.g. with a pumping screw. The QFT3000 stainless steel tank is equipped with a sight-glass for monitoring the MIN filling level and can be fastened with a lug fixture.

Supply of mechanical seal based on API 682 / ISO 21049, Plan 51.
Contact

Inquire about individual solutions

We develop and produce customer-specific special and individual solutions for every application.

Inquire now Discover reference projects
Back to the overview